Valve-in-Valve TAVI como opción a la reoperación en disfunción de bioprótesis valvulares de colocación quirúrgica

Autores/as

  • Diego Agustín Crippa Servicio de Ecocardiografía Doppler. Sanatorio Finochietto. Buenos Aires. Argentina
  • Adrián Lescano Servicio de Ecocardiografía Doppler. Sanatorio Finochietto. Buenos Aires. Argentina
  • Victor Darú Servicio de Ecocardiografía Doppler. Sanatorio Finochietto. Buenos Aires. Argentina
  • Matías Sztejfman Servicio de Cardiología Intervencionista. Sanatorio Finochietto. Buenos Aires. Argentina
  • Nicolás González Servicio de Cardiología. Sanatorio Finochietto. Buenos Aires. Argentina

DOI:

https://doi.org/10.37615/retic.v1n2a6

Palabras clave:

implante valvular aórtico transcatéter (TAVI), valve-in-valve TAVI, disfunción de bioprótesis valvulares.

Resumen

El implante valvular aórtico transcatéter (TAVI) es una opción de tratamiento ya establecida en pacientes con este- nosis aórtica severa y elevado riesgo quirúrgico. Actualmente se estudian otras indicaciones en las que puede tener beneficio, como la disfunción de bioprótesis valvulares en pacientes con elevado riesgo de reoperación. En estos casos se realiza el implante percutáneo de una válvula dentro del anillo de la prótesis quirúrgica colocada previamente en un procedimiento denominado valve-in-valve (VIV TAVI). En este artículo se describen dos casos de disfunción de bioprótesis por insuficiencia grave en los que el tratamiento endovascular solucionó el problema clínico.

Descargas

Los datos de descargas todavía no están disponibles.

Métricas

Cargando métricas ...

Citas

Walther T, Falk V, Dewey T, et al. Valve-in-a-valve concept for transcatheter minimally invasive repeat xenograft implantation. J Am Coll Cardiol 2007; 50: 56-60. DOI: https://doi.org/10.1016/j.jacc.2007.03.030

Eggebrecht H, Schafer U, Treede H, et al. Valve-in-valve transcatheter aortic valve implantation for degenerated bioprosthetic heart valves. JACC Cardiovasc Interv 2011; 4: 1218-1227. DOI: https://doi.org/10.1016/j.jcin.2011.07.015

Webb JG, Wood DA, Ye J, et al. Transcatheter valve-in-valve implantation for failed bioprosthetic heart valves. Circulation 2010; 121: 1848-1857. DOI: https://doi.org/10.1161/CIRCULATIONAHA.109.924613

Dvir D, et al. Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the global valve-in-valve registry. Circulation 2012; 126 (19): 2335-2344. DOI: https://doi.org/10.1161/CIRCULATIONAHA.112.104505

Bapat V. Valve-in-valve apps: why and how they were developed and how to use them. EuroIntervention 2014; 10 Suppl U: U44-51. DOI: https://doi.org/10.4244/EIJV10SUA7

Bapat V. Technical pitfalls and tips for the valve-in-valve procedure. Ann Cardiothorac Surg 2017; 6 (5): 541-552. DOI: https://doi.org/10.21037/acs.2017.09.13

Blanke P, Soon J, Dvir D, et al. Computed tomography assessment for transcatheter aortic valve in valve implantation: The Vancouver approach to predict anatomical risk for coronary obstruction and other considerations. J Cardiovasc Comput Tomogr 2016; 10: 491-499. DOI: https://doi.org/10.1016/j.jcct.2016.09.004

Jones JM, et al. Repeat heart valve surgery: risk factors for operative morta- lity. J Thorac Cardiovasc Surg 2001; 122: 913-918. DOI: https://doi.org/10.1067/mtc.2001.116470

Roy Beigel, et al. Aortic Valve Implantation for failed Bio-Bentall in patients with Marfan Syndrome. Cardiology 2014; 128: 9-12. DOI: https://doi.org/10.1159/000357265

Descargas

Publicado

2018-08-31

Cómo citar

1.
Crippa DA, Lescano A, Darú V, Sztejfman M, González N. Valve-in-Valve TAVI como opción a la reoperación en disfunción de bioprótesis valvulares de colocación quirúrgica. Rev Ecocardiogr Pract Otras Tec Imag Card (RETIC) [Internet]. 31 de agosto de 2018 [citado 21 de noviembre de 2024];1(2):23-7. Disponible en: https://imagenretic.org/RevEcocarPract/article/view/153

Artículos más leídos del mismo autor/a

Artículos similares

También puede {advancedSearchLink} para este artículo.