Embolisation of occluder device in closure of mitral paravalvular leakage

Authors

  • José María Hernández-Hernández Servicio de Ecocardiografía. Hospital de Cardiología 34 IMSS Monterrey. Nuevo León. México
  • Josue Silva-Ortiz Laboratorio de Ecocardiografía. Hospital Universitario Dr. “J. Eleuterio González” UANL. Monterrey. Nuevo León. México
  • Raquel Vega-Hernández Servicio de Cirugía Cardiovascular y Torácica. Hospital de Cardiología 34 IMSS Monterrey. Nuevo León. México
  • Bertha Gaxiola-Cadena Jefe del Servicio de Gabinete de Cardiología. Hospital de Cardiología 34 IMSS Monterrey. Nuevo León. México

DOI:

https://doi.org/10.37615/retic.v1n2a4

Keywords:

paravalvular leak, oclusor device.

Abstract

Clinically significant paravalvular regurgitation is a serious complication in patients with valvular prosthesis. We presented the clinical case of a 58 years old woman with mitral paravalvular leak and dyspnea in a poor functional class in whom a percutaneous closure of the leak was performed, complicated in the follow-up with embolization of the device. The echocardiogram provides essential information on the characteristics of the dehiscence, prior and during the procedure, as well as in the short and long term follow-up.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Rozas M, López García MI, Puñal Riobóo J. Cierre de fugas perivalvulares en prótesis valvulares mediante dispositivo Amplatzer. Plan de Calidad para el Sistema Nacional de Salud del Ministerio de Sanidad, Política Social e Igualdad. Axencia de Avaliación de Tecnoloxías Sanitarias de Galicia, 2012. Informes de evaluación de tecnologías sanitarias: avalia-t Núm. 2011/1-3.

Rihal C, Sorajja P, Booker J, et al. Principles of Percutaneous Paravalvular Leak Closure. JACC: Cardiovascular Interventions 2012; 5: 121-130. DOI: https://doi.org/10.1016/j.jcin.2011.11.007

Ionescu A, Fraser AG, Butchart EG. Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transesophageal echocardiography. Heart 2003; 89: 1.316-1.321. DOI: https://doi.org/10.1136/heart.89.11.1316

Cruz-González I, Rama-Merchan J, Arribas-Jimenes A, et al. Cierre percutáneo de fugas periprotésicas con el dispositivo Amplatzer Vascular Plug III: resultado inmediatos y a corto plazo. Rev Esp Cardiol 2014; 67 (8): 608-614. DOI: https://doi.org/10.1016/j.recesp.2013.09.033

Sorajja P, Cabalka A, Hagler D, Rihal C. Long-Term Follow-Up of Percutaneous Repair of Paravalvular Prosthetic Regurgitation. J Am Coll Cardiol 2011; 58: 2.218-2.224. DOI: https://doi.org/10.1016/j.jacc.2011.07.041

Ruiz C, Jelnin V, Kronzon I, et al. Clinical Outcomes in Patients Undergoing Percutaneous Closure of Periprosthetic Paravalvular Leaks. J Am Coll Cardiol 2011; 58: 2.210-2.217. DOI: https://doi.org/10.1016/j.jacc.2011.03.074

García-Fernández MA, Cortés M, García-Robles J, et al. Utility of Real-Time Three-Dimensional Transesophageal Echocardiography in Evaluating the Success of Percutaneous Transcatheter Closure of Mitral Paravalvular Leaks. J Am Soc Echocardiogr 2010; 23: 26-32. DOI: https://doi.org/10.1016/j.echo.2009.09.028

Cortés M, García E, García-Fernández MA, et al. Usefulness of transesophageal echocardiography in percutaneous transcatheter repairs of paravalvular mitral regurgitation. Am J Cardiol 2008; 101: 383-386. DOI: https://doi.org/10.1016/j.amjcard.2007.08.052

Published

2018-08-31

How to Cite

1.
Hernández-Hernández JM, Silva-Ortiz J, Vega-Hernández R, Gaxiola-Cadena B. Embolisation of occluder device in closure of mitral paravalvular leakage. Rev Ecocardiogr Pract Otras Tec Imag Card (RETIC) [Internet]. 2018 Aug. 31 [cited 2024 Nov. 23];1(2):15-8. Available from: https://imagenretic.org/RevEcocarPract/article/view/24