Síndrome de platipnea-ortodeoxia por foramen oval permeable diagnosticado mediante ecocardiografía

Autores/as

  • Alberto Funes Almendros Instituto Cardiovascular, Cardiología. Hospital Clínico San Carlos, Madrid, España. https://orcid.org/0009-0000-3668-326X
  • Yassin Daoud Instituto Cardiovascular, Cardiología. Hospital Clínico San Carlos, Madrid, España.
  • Asier Rubio Martínez Instituto Cardiovascular, Cardiología. Hospital Clínico San Carlos, Madrid, España. https://orcid.org/0009-0004-8451-9666
  • Óscar García Durán Instituto Cardiovascular, Cardiología. Hospital Clínico San Carlos, Madrid, España. https://orcid.org/0009-0004-5781-4803
  • Miriam García Cocera Instituto Cardiovascular, Cardiología. Hospital Clínico San Carlos, Madrid, España. https://orcid.org/0009-0009-3667-9565

DOI:

https://doi.org/10.37615/retic.v9n2a8

Palabras clave:

síndrome de platipnea-ortodeoxia, foramen oval permeable, ecocardiografía con contraste, shunt derecha-izquierda

Resumen

Se presenta el caso de una mujer de 71 años ingresada por episodios de disnea y desaturación con comportamiento postural con desaturación en bipedestación y mejoría en decúbito, sugestivo de síndrome de platipnea-ortodeoxia. El estudio con ecocardiograma transtorácico y transesofágico mostró un foramen oval permeable de gran tamaño con shunt significativo. El cierre del defecto con un dispositivo tipo Amplatzer ™ resolvió de forma completa los síntomas.

Descargas

Los datos de descargas todavía no están disponibles.

Citas

Agrawal A, Palkar A, Talwar A. The multiple dimensions of platypnea-orthodeoxia syndrome: A review. Respir Med. 2017;129:31-38. doi: https://doi.org/10.1016/j.rmed.2017.05.016

Cheng TO. Platypnea-orthodeoxia syndrome: etiology, differential diagnosis, and management. Catheter Cardiovasc Interv. 1999;47(1):64-66. doi: https://doi.org/10.1002/(SICI)1522-726X(199905)47:1<64::AID-CCD15>3.0.CO;2-6

Mojadidi MK, Gevorgyan R, Noureddin N, Tobis JM. The effect of patent foramen ovale closure in patients with platypnea-orthodeoxia syndrome. Catheter Cardiovasc Interv. 2015;86(4):701-707. doi: https://doi.org/10.1002/ccd.25998

Bertaux G, Eicher JC, Petit A, Dobšák P, Wolf JE. Anatomic interaction between the aortic root and the atrial septum: a prospective echocardiographic study. J Am Soc Echocardiogr. 2007;20(4):409-414. doi: https://doi.org/10.1016/j.echo.2006.09.007

Sanikommu V, Lasorda D, Poornima I. Anatomical factors triggering platypnea-orthodeoxia in adults. Clin Cardiol. 2009;32(11):E55-E57. doi: https://doi.org/10.1002/clc.20520

Rodrigues P, Palma P, Sousa-Pereira L. Platypnea-orthodeoxia syndrome in review: defining a new disease? Cardiology. 2012;123(1):15-23. doi: https://doi.org/10.1159/000338798

Guerin P, Lambert V, Godart F, et al. Transcatheter closure of patent foramen ovale in patients with platypnea-orthodeoxia: results of a multicentric French registry. Cardiovasc Intervent Radiol. 2005;28(2):164-168. doi: https://doi.org/10.1007/s00270-004-0151-8

Blanche C, Noble S, Roffi M, et al. Platypnea-orthodeoxia syndrome in the elderly treated by percutaneous patent foramen ovale closure: a case series and literature review. Eur J Intern Med. 2013;24(8):813-817. doi: https://doi.org/10.1016/j.ejim.2013.05.013

Descargas

Publicado

2026-08-24

Cómo citar

1.
Funes Almendros A, Daoud Y, Rubio Martínez A, García Durán Óscar, García Cocera M. Síndrome de platipnea-ortodeoxia por foramen oval permeable diagnosticado mediante ecocardiografía. Rev Ecocardiogr Pract Otras Tec Imag Card (RETIC) [Internet]. 24 de agosto de 2026 [citado 26 de agosto de 2026];9(2):39-43. Disponible en: https://imagenretic.org/RevEcocarPract/article/view/807